Product Description
PLD7600A High Frequency Radiography System Mobile Portable X-ray Machine
Application:
It can be applied to take fluoroscopy on chest and abdomen, gastrointestinal contrast, cholangiography, lower vein angiography, urography and etc; take digital radiography on head, chest, abdomen, limbs and etc; repair fracture and take foreign matter under fluoroscopy.
Configuration:
1. Control console 1 set
2. High voltage generator 1 set
3. X-ray tube assembly 1 set
4. Electrical collimator 1 set
5. High voltage cable 2 pcs
6. Diagnostic table 1 set
7. Specific Grid for DR Machine 1 pc
8. Image Intensifier 1 pc
9. CCD Camera 1 set
10. Flat Panel Detector 1 set
11. LCD Monitor 1 pc
12. CRT monitor 1 pc
13. DR acquisition workstation 1 set
14. Accessories for PLD7600A 1 set
Main Parameters:
Item | Content | Value |
Power supply | Voltage | 380V±38V |
Frequency | 50Hz±1Hz |
Capacity | 63kVA |
Inner resistance | 0.17Ω |
High frequency high voltage generator | | Power output | 50kW |
| Main invert frequency | 60kHz |
Radiography | Tube voltage | 40kV-150kV |
Tube current | 10mA-640mA |
Exposure time | 1ms-10000ms |
Fluoroscopy | Tube voltage | 40kV-125kV |
Tube current | 0.5mA-6mA |
Exposure time | 0-10min |
X-ray tube assembly | Output power | Large focus: 50kW Small focus: 20kW |
Anode thermal capacity | 215kJ (300kHU) |
Tube thermal capacity | 900kJ (1250kHU) |
Tube focus | 1.2mm / 0.6mm |
Remote diagnostic table | Rotary range | 90°~0°~-25° |
Transverse movement range | 220mm |
Longitudinal movement range | ≥720mm |
SID | 1100mm-1500mm |
Spot film partition method | Full film, half film, one thrid film, quarter film |
Diagnostic control method | Remote control Close table control Soft start and stop |
Collimator | Electrical multi-leaf |
Fixed filter | Density: 103L/INCH, ratio: 10:1, focal distance: 110cm, 15''×18'' |
TV Image System | Image Intensifier | Thales 23XZ4 |
0.4 Mega Pixels CCD | CXD Japan Watec 902B |
CRT Monitor | 14 medical high definition monitor, horizontal central resolution ratio :1000 lines ,fringe: 800 lines ,video bandwidth:12.5MHz ,50bit,image number/second: 25 frame |
Toshiba fixed flat panel detector | Effective area | 430(H)×439(V) |
Pixels matrix | 3008(H)×3072(V) |
Pixels space | 143 μm |
Cycle time | 6S |
Space resolution | Min. 3.5 line pair |
A/D exchange | 14 bit |
Energy area | 40 ~ 150 kVp |
Max entrance dose | 4 mR / frame(low gain) |
Data output | 16 bit numeric output Ethernet (1000BASE - T) |
Command control | Ethernet (1000BASE - T) |
Sensor protective plate | Carbon fibre |
DR acquisition workstation | Computer system | Brand: DELL OPTIPLEX 7010 business use desktop Processor: Core i5-3570 RAM: 4GB DDR3 Hard disk: 500GB 7200r, SATA Graphics: Intel GMA HD 3000 Integrated Intel 82579LM kilomega Ethernet LAN 10/100/1000 CD-ROM: Suitable for MT 16X variable speed DVD+/-RW, with double level read-in function Network card: BroadcomNetXtreme10/100/1000 PCIe fast Ethernet card. Graphics: 1GB AMD RADEON HD 7570, FH, with DVI-VGA Adapter Interface: PCIE serial and parallel port, Full-HD, MT |
| Monitor | Dell professional P1913S 19" monitor |
| Workstation software | DROC or QXvue and software dongle |